Composite Suspension Insulator

Composite Suspension Insulators are electrical components designed specifically for suspension applications in high-voltage electrical systems. They consist of a core material made of insulating silicone rubber or other polymer materials, surrounded by a weather-resistant, flexible outer shell. The suspension insulators are suspended from overhead power lines and provide electrical insulation between the conductor and the support structure.

Get A Quote PDF Datasheet
Composite Suspension Insulator

Composite Suspension Insulator voltage class:

11kV, 12kV,15kV,24kV, 33kV, 36kV,69kV, 110kV, 132kV, 138kV,169kV, 220kV, 245kV, 330kV, 400kV, 420kV, 500kV 750kV

Composite Suspension Insulator Specific Mechanical load:

40kN,50kN, 70kN, 100kN, 110kN, 120kN, 160kN, 210kN

Composite Suspension Insulator Standard of execution

IEC61109, IEC61952, IECC29.11

 

Composite Suspension Insulator Mark of gold instrument:

11R Type Composite Suspension Insulator Mark of Gold Instrument 16R Type Composite Suspension Insulator Mark of Gold Instrument 16W Type Composite Suspension Insulator Mark of Gold Instrument 20R Type Composite Suspension Insulator Mark of Gold Instrument

 

D Type Composite Suspension Insulator Mark of Gold Instrument U Type Composite Suspension Insulator Mark of Gold Instrument Y Type Composite Suspension Insulator Mark of Gold Instrument O Type Composite Suspension Insulator Mark of Gold Instrument

 

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
1 11 70 325±5 220±5 430 125/110 110 42

11KV 325±5mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
2 12 70 350±10 226±5 475 99±1 125 50

12KV 350±10mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
3 24 70 430±15 314±5 690 99±1 150 75

24KV 430±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
4 33 70 530±15 400±5 925 99±1 150 75

33KV 530±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
5 36 70 590±15 475±5 1200 98/69 210 95

36KV 590±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
6 36 70 570±15 448±5 1040 99±1 170 90

36KV 570±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
7 33 25 700±15 505±5 1350 140/110 230 95

33KV 700±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
8 36 100 645±15 505±5 1350 140/110 230 95

36KV 645±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
9 33 40 330±15 270±5 730 131/90 170 75

33KV 330±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
10 66 70 877±15 730±5 2150 140/108 420 120

66KV 877±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
11 132 70 1350±15 1230±5 3850 140/108 820 240

132KV 1350±15mm Minimum ARC Distance Composite Suspension Insulator

NO. Rated voltage

(kV)

Rated mechanical tensile load

(KN)

The height of the structure (mm) Minimum arc distance(mm) The minimum nominal creepage distance(mm) The diameter of umbrella(mm) Lightning impulse withstand voltage (peak)(kV) Power frequency withstand voltage 1min(kV)
12 220 120 2316±15 2138±5 6930 140/108 1360 400

220KV 2138±5mm Minimum ARC Distance Composite Suspension Insulator

 

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
Arrester Fittings

Disconnector Surge Arresters Manufacturers | IEC & IEEE Standards Compliant

Leading manufacturer of disconnector surge arresters, meeting IEC & IEEE standards. Trusted quality for safe, efficient power system protection worldwide.

Reliable Disconnector Surge Arresters Manufactured to IEC & IEEE Standards

As a trusted manufacturer specializing in disconnector surge arresters, we offer products fully compliant with IEC and IEEE standards. Our surge arresters provide reliable overvoltage protection for power systems, ensuring safety and operational efficiency. With advanced manufacturing facilities and rigorous quality control, we deliver superior performance at competitive prices.

A. About Our Disconnector Surge Arresters

  • Overview of product features

  • Importance of disconnector functionality in surge protection

  • Compliance with IEC 60099 and IEEE C62 series standards

B. Manufacturing Excellence

  • Description of factory capabilities

  • Quality assurance processes

  • Use of premium materials and technology

C. Industry Standards Explained

  • Explanation of IEC & IEEE standards relevant to surge arresters

  • Why compliance matters for safety and reliability

D. Applications & Benefits

  • Typical applications in power distribution and transmission

  • Benefits such as improved equipment lifespan, reduced downtime, and enhanced safety

E. Why Choose Us?

  • Experience and expertise (e.g., 10+ years in manufacturing)

  • Competitive pricing and fast delivery

  • Customization options and customer support

6. Call to Action (CTA)

Contact us today for detailed product catalogs, pricing, and custom solutions tailored to your power system needs.

7. FAQ Section (Schema Markup Friendly)

  • What are disconnector surge arresters?

  • What standards do your surge arresters comply with?

  • How to choose the right surge arrester for my project?

  • What is the typical delivery time?

VIEW MORE >>
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator