Composite Post Insulator

Advantages for composite line post insulator:

Compare to porcelain line post insulator, composite insulator line post is the ideal solution for compact line applications in urban areas and composite line post insulator is also ideal for upgrading the capacity of existing lines with a narrow right of way – by increasing the voltage or the number of circuits. It also has the following key advantages:

1. Can be installed on steel, concrete and wood poles

Get A Quote PDF Datasheet
Composite Post insulator

 

Composite Post Insulators: An Advanced Solution for Electrical Transmission and Distribution Systems. Made from high-quality composite materials, these insulators offer superior performance, durability, and reliability compared to traditional insulators, making them an ideal choice for demanding power transmission and distribution applications.

NO. Product model Rated mechanical failure load The height of the structure(mm) Minimum arc distance

(mm)

The minimum nominal creepage distance(mm) Standard full lightning impulse withstand voltage (peak) (kV) 1min power frequency wet withstand voltage (RMS) not less than(kV) The maximum operating voltage equipment

(KV)

Bend(KN) Reverse(KN.m)
1 FZSW3-12/5 5 0.6 215 130 380 75 45 12

 

FZSW3-12/5 12KV 380mm Minimum Arc Distance Composite Post Insulator

 

NO. Product model Rated mechanical failure load The height of the structure(mm) Minimum arc distance

(mm)

The minimum nominal creepage distance(mm) Standard full lightning impulse withstand voltage (peak) (kV) 1min power frequency wet withstand voltage (RMS) not less than(kV) The maximum operating voltage equipment

(KV)

Bend(KN) Reverse(KN.m)
2 FZSW3-24/8 80 4 320 220 580 120 60 24

 

FZSW3-24/8 24KV 220mm Minimum Arc Distance Composite Post Insulator

 

NO. Product model Rated mechanical failure load The height of the structure(mm) Minimum arc distance

(mm)

The minimum nominal creepage distance(mm) Standard full lightning impulse withstand voltage (peak) (kV) 1min power frequency wet withstand voltage (RMS) not less than(kV) The maximum operating voltage equipment

(KV)

Bend(KN) Reverse(KN.m)
3 FZSW-35/5 5 2 450 300 1200 230 95 35

 

FZSW-35/5 35KV 300mm Minimum Arc Distance Composite Post Insulator

 

NO. Product model Rated mechanical failure load The height of the structure(mm) Minimum arc distance

(mm)

The minimum nominal creepage distance(mm) Standard full lightning impulse withstand voltage (peak) (kV) 1min power frequency wet withstand voltage (RMS) not less than(kV) The maximum operating voltage equipment

(KV)

Bend(KN) Reverse(KN.m)
4 FZSW3-40.5/6 6 1.5 500 380 1220 230 95 40.5

 

FZSW3-40.5/6 40.5KV 380mm Minimum Arc Distance Composite Post Insulator

 

NO. Product model Rated mechanical failure load The height of the structure(mm) Minimum arc distance

(mm)

The minimum nominal creepage distance(mm) Standard full lightning impulse withstand voltage (peak) (kV) 1min power frequency wet withstand voltage (RMS) not less than(kV) The maximum operating voltage equipment

(KV)

Bend(KN) Reverse(KN.m)
5 FZS3-72.5/8 8 2 770 635 1820 325 140 72.5

 

FZSW3-24/8 35KV 300mm Minimum Arc Distance Composite Post Insulator

 

NO. Product model Rated mechanical failure load The height of the structure(mm) Minimum arc distance

(mm)

The minimum nominal creepage distance(mm) Standard full lightning impulse withstand voltage (peak) (kV) 1min power frequency wet withstand voltage (RMS) not less than(kV) The maximum operating voltage equipment

(KV)

Bend(KN) Reverse(KN.m)
6 FZSW3-110/8 8 2 770 635 1820 325 140 72.5

 

FZSW3-110/8 Minimum Arc Distance 635mm Composite Post Insulator

 

NO. Product model Rated mechanical failure load The height of the structure(mm) Minimum arc distance

(mm)

The minimum nominal creepage distance(mm) Standard full lightning impulse withstand voltage (peak) (kV) 1min power frequency wet withstand voltage (RMS) not less than(kV) The maximum operating voltage equipment

(KV)

Bend(KN) Reverse(KN.m)
7 FZSW3-220/10 10 4 760 610 1820 325 140 72.5

 

FZSW3-220/10 610mm Minimum Arc Distance Composite Post Insulator

 

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
Arrester Fittings

Disconnector Surge Arresters Manufacturers | IEC & IEEE Standards Compliant

Leading manufacturer of disconnector surge arresters, meeting IEC & IEEE standards. Trusted quality for safe, efficient power system protection worldwide.

Reliable Disconnector Surge Arresters Manufactured to IEC & IEEE Standards

As a trusted manufacturer specializing in disconnector surge arresters, we offer products fully compliant with IEC and IEEE standards. Our surge arresters provide reliable overvoltage protection for power systems, ensuring safety and operational efficiency. With advanced manufacturing facilities and rigorous quality control, we deliver superior performance at competitive prices.

A. About Our Disconnector Surge Arresters

  • Overview of product features

  • Importance of disconnector functionality in surge protection

  • Compliance with IEC 60099 and IEEE C62 series standards

B. Manufacturing Excellence

  • Description of factory capabilities

  • Quality assurance processes

  • Use of premium materials and technology

C. Industry Standards Explained

  • Explanation of IEC & IEEE standards relevant to surge arresters

  • Why compliance matters for safety and reliability

D. Applications & Benefits

  • Typical applications in power distribution and transmission

  • Benefits such as improved equipment lifespan, reduced downtime, and enhanced safety

E. Why Choose Us?

  • Experience and expertise (e.g., 10+ years in manufacturing)

  • Competitive pricing and fast delivery

  • Customization options and customer support

6. Call to Action (CTA)

Contact us today for detailed product catalogs, pricing, and custom solutions tailored to your power system needs.

7. FAQ Section (Schema Markup Friendly)

  • What are disconnector surge arresters?

  • What standards do your surge arresters comply with?

  • How to choose the right surge arrester for my project?

  • What is the typical delivery time?

VIEW MORE >>
GET A QUOTE TODAY!
icon
icon