Composite Suspension Insulator voltage class:
11kV, 12kV,15kV,24kV, 33kV, 36kV,69kV, 110kV, 132kV, 138kV,169kV, 220kV, 245kV, 330kV, 400kV, 420kV, 500kV 750kV
Composite Suspension Insulator Specific Mechanical load:
40kN,50kN, 70kN, 100kN, 110kN, 120kN, 160kN, 210kN
Composite Suspension Insulator Standard of execution
IEC61109, IEC61952, IECC29.11
Composite Suspension Insulator Mark of gold instrument:
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
1 |
11 |
70 |
325±5 |
220±5 |
430 |
125/110 |
110 |
42 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
2 |
12 |
70 |
350±10 |
226±5 |
475 |
99±1 |
125 |
50 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
3 |
24 |
70 |
430±15 |
314±5 |
690 |
99±1 |
150 |
75 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
4 |
33 |
70 |
530±15 |
400±5 |
925 |
99±1 |
150 |
75 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
5 |
36 |
70 |
590±15 |
475±5 |
1200 |
98/69 |
210 |
95 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
6 |
36 |
70 |
570±15 |
448±5 |
1040 |
99±1 |
170 |
90 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
7 |
33 |
25 |
700±15 |
505±5 |
1350 |
140/110 |
230 |
95 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
8 |
36 |
100 |
645±15 |
505±5 |
1350 |
140/110 |
230 |
95 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
9 |
33 |
40 |
330±15 |
270±5 |
730 |
131/90 |
170 |
75 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
10 |
66 |
70 |
877±15 |
730±5 |
2150 |
140/108 |
420 |
120 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
11 |
132 |
70 |
1350±15 |
1230±5 |
3850 |
140/108 |
820 |
240 |
NO. |
Rated voltage
(kV) |
Rated mechanical tensile load
(KN) |
The height of the structure (mm) |
Minimum arc distance(mm) |
The minimum nominal creepage distance(mm) |
The diameter of umbrella(mm) |
Lightning impulse withstand voltage (peak)(kV) |
Power frequency withstand voltage 1min(kV) |
12 |
220 |
120 |
2316±15 |
2138±5 |
6930 |
140/108 |
1360 |
400 |