At present, the following process of urban and rural 10KV insulation process soon, but the pole on the distribution area of the widespread existence of switches, arrester, connecting clamps, pillars and other parts of the connection to bring more trouble points, poor insulation security conditions, installation complex, Difficult and high cost, poor live conditions and other series of problems. In order to deal with the above problems, it is necessary to transform some of the equipment and line connection of the pole change system so as to achieve the purpose of simplifying the device and further increasing the safety of operation. HY5WBG-17/50 synthetic jacket zinc oxide arrester device with a pillar function, arrester function, puncture power function, power test grounding function of the four functions as a whole, with a multi-purpose structure. The use of this device can also reduce the arrester cross arm (due to the use of the required pillars crossed); can reduce the vertical fixation of the three insulators; that is, to reduce the seven stripping points, reduce the number of construction time, while reducing six At the point of failure, you can achieve a simplified line device, and further increase the safety and reliability of the purpose of running, so that the line is more simple and beautiful. In addition, this device integrates a variety of functions, the original need to be stripped of the seven points of insulation and insulation in a, and this insulation cover design is reasonable, can really do the whole insulation, for safe and live operation to create favorable conditions The

figure 1

◆ conditions of use

1. Ambient temperature: ± 50 ℃

2. Altitude: no more than 2000m

3. Wind speed: no more than 35m / s

4. Pollution Level III

5. No flammable, explosive buildings where the strong vibration

◆ Main technical parameters

Serial number

serial number

product number


arrester rated voltage KV
(peak)



system nomminal  voltage kv(rms)



arrester

continued

running kv(rms)



dc 1ma referrence voltage not less than 1kv(rms)



lightning impact  current silicon pressure not dry kv (rms)



current shock 2ms square wave cureet a(peak)



high current pressure  release the expacted pair called current ka(peak)



bending strong degree n


1

HY5WBG-17/50

17

10

13.6

25

50

100

25

10000

2

HY5WBG-17/50T

17

10

13.6

25

50

100

25

10000

3

HY5WDG-17/50

17

10

13.6

25

50

100

25

10000

4

HY5WDG-17/50T

17

10

13.6

25

50

100

25

10000

5

HY5WDG-34/90

34

24

27.2

50

90

250

25

10000

6

HY5WDG-34/90T

34

24

27.2

50

90

250

25

10000

ORDER NOW >> enter Higher Quantity (over 200) to Request a Quote <<
For more Other high-voltage products. please contact a sales representative at sale16@gotoelectrical.com or submit a Quote Request.

Send Inquiry
Submitting now, please wait...
Send Subscribing
newsletter
Thank you for subscribing to updates from Feizhou Power!
Thank you for registering for email from Feizhou Power. We are excited that you have joined the group. You will receive your first welcome message soon. It will describe the email program and what to expect in the upcoming weeks. Enjoy!